slider

Introduction

The regulators R - 2402, R - 4108 are mainly used for ammonia gas. The trim parts for these regulators are of stainless steel. R - 4108 is preset type regulator & is mainly used as second stage pressure regulator. R - 2402 is adjustable pressure regulator & is mainly used as first stage pressure regulator.

R - 2703 is a fine control adjustable pressure regulator which is used when precision pressure control is required for instrumentation purpose like Air - Gauges. We also manufacture regulators suitable for corrosive gases like Cl2, SO2 etc.

Type of Regulator Inlet Pressure Range Outlet Pressure Range Gas Flow Rate End Connection Gas
R2301-I 1 - 19 Kg/cm2 0.5 to 10 Kg/cm2 100 Nm3/hr 1" BSP (INT) Ammonia
R4110-I 1 - 17 Kg/cm2 0.03 - 0.3 Kg/cm2 30 Nm3/hr Inlet: 1/2" / 3/4" / 1" BSP (INT)
Outlet: 1/2" / 3/4" / 1" BSP (INT)
Ammonia
R2402 22 Kg/cm2 0.5 - 4 Kg/cm2 25 Nm3/hr 1/2" BSP (INT) (Union Nut) Ammonia
R4108 1 - 5 Kg/cm2 (a) 0.03 - 0.15 Kg/cm2
(b) 0.15 - 0.3 Kg/cm2
(c) 0.3 - 0.7 Kg/cm2
(d) 0.7 - 1 Kg/cm2
10 Nm3/hr
30 Nm3/hr
30 Nm3/hr
30 Nm3/hr
Inlet: 1/2" BSP (INT) Union Nut
Outlet: 1/2" BSP (INT)
Ammonia
R2325 1 - 19 Kg/cm2 0.5 - 8 Kg/cm2 0 - 120 Nm3/hr 1" BSP (INT) Medical Oxygen
R2703 2 - 10 Kg/cm2 1.75 + 0.05 Kg/cm2 1 Nm3/hr 1/8" NPT (INT) Nitrogen & Air